Assembly Instructions: 1208-9 DNI (Marcellis)
IMPORTANT:
• ALL INSTALLATION WORK SHOULD BE DONE BY ACCREDITED PROFESSIONAL.
• SHUT OFF POWER SUPPLY AT FUSE OR CIRCUIT BREAKER!
• USE ONLY THE SPECIFIED BULBS. DO NOT EXCEED THE MAXIMUM WATTAGE!
PREPARING FOR INSTALLATION
Carefully remove all of the contents from the carton. See the
important notes above. Shut off the power at the circuit breaker
andcompletelyremovetheoldxturefromthewall,including
theoldmountingstrap.
Fromthepartsbagremovethemountingstrapassembly.One
endofnipple(F)shouldbeattachedtomountingstrap(A)with
washerandhexnuts(C&D)inplace.Theotherendshouldhave
canopy loop (H) attached.
Attachmountingstrap(A)tothejunctionboxusingmounting
screws(B)andascrewdriver.Tightensecurely.Unscrewcanopy
loop collar (I) from canopy loop (H). Pass canopy (G) over the
mountedcanopylooptotesttheheight.Approximatelyhalf
ofthecanopyloop’sexteriorthreadsshouldbeexposed,and
thecanopyloopcollarshouldtsnuglyontothecanopyloop.
Removecanopy(G)andadjusttheheightofnipple(F)and
canopyloop(H)untilthedesiredheightisreached.
Bymeasuring,determinethecorrectamountofchainandwire
neededforproperhangingheight.Ifnecessary,useapairof
plierstoopenandremoveanyexcesschain.Attachoneofchain
connectors(K)toeachendofchain(J).Passthexturewires
throughtoploop(H).Attachoneendofchain(J)totoploop
(L)usingchainconnector(K)andclosechainconnector(K).
Attach one end of rods (O) to the decorative hooks on top cap
(M). Hook the other end of rods (O) to decorative hooks (R) on
xtureframering(P).Attachoneendofrods(Q)tothebottom
ofdecorativehook(R).Thenattachtheotherendofrod(Q)to
decorativehooks(S)onxtureframering(U).Feedthexture
wiresupthroughthechain(everythreelinksorso),pullingthe
wiresuntiltaut.Trimthewirestothedesiredlengthplus8to10
inches.
CONNECTING THE WIRES
Haveanassistantsupportthextureweightwhilecompleting
thewiring.Threadthexturewiresthroughcanopy(G).Attach
thexture’swirestothepowersupplywiresfromthejunction
box.Connectblacktoblack(orsmooth);whitetowhite(or
ribbed);groundtoground(greenorcopper).Twisttheendsof
thewirepairstogether,thentwistonawireconnector.Make
surealltwistsareinthesamedirection.Ifthereisnogroundwire
(greenorcopper)fromthejunctionbox,locategroundscrew(E)
onmountingstrap(B)andwrapthexturegroundwirearound
thegreengroundscrew(E).Useascrewdrivertosecureground
screw(E)ontothemountingbracket.Tuckallwiresneatlyinto
thejunctionbox.
FINISHING THE INSTALLATION
Note: Completetheremainingstepsafterthextureishung.
Tightenthedecorativehammerednials(T)ontothethreadsat
thebottomofxtureframe(P)and(U)
Carefullyslideglassshades(W)oversockets(Y).Candlesleeves
(X)haveretainingringsattached.Eachretainingringhastwo
smallholesineachside.Theglassshadeopeningistight.
Carefullypushthecandlesleevesdownintotheglassshades
and over the sockets. Carefully place the tips of socket tool (V)
intotheholesintheretainingring.Usesockettool(V)tothread
theretainingringsontothesocketthreads.Thiswillsecurethe
glassinplace.
Installlightbulbsinaccordancewiththexture’sspecications.
Donotexceedthemaximumrecommendedwattage.
Your installation is now complete. Turn on the power and test the
xture.
CLEANING TIPS
Treat the xture gently! Regular cleaning will reduce the need for deep cleaning. For regular cleaning, turn off the light and wipe down the
xture with a clean lint-free cotton or microber cloth. Never spray cleaner directly onto the xture.
For Customer Service, contact
the place of purchase to arrange
for replacement parts.
BLACK
(Hot)
WHITE
(Neutral)
GREEN
(Ground)
HOUSE WIRES
SMOOTH
(Or Black)
FIXTURE WIRES
RIBBED
(Or White)
BARE COPPER
(Or Green)
A
G
E
B
F
M
V
W
X
Y
O
P
Q
U
H
J
K
L
R
S
T
C
D
I
N
Comments to this Manuals